摘要: |
针对研究区域地下水高氯化物、高铁离子等水质特征,通过开展多次自动分析仪与实验室手工比对监测,验证了氨氮、耗氧量、锰、氯化物等水质参数自动监测分析方法在地下水中的适用性。结果表明,在有针对性的采取更换仪器分析方法、改进前处理、优化管路集成等措施后,各水质参数自动监测与实验室手工比对监测结果基本一致,可为下来进一步建立统一、规范的地下水水质自动监测技术体系提供经验和参考。 |
关键词: 地下水 水质 自动监测 适用方法 |
DOI: |
分类号: |
基金项目: |
|
A preliminary study on the applicable methods and conditions of automatic monitoring of groundwater quality |
|
Abstract: |
According to the water quality characteristics of groundwater such as perchloride and ferric ions in the study area, the applicability of automatic monitoring for water quality parameters such as ammonia nitrogen, oxygen consumption, manganese and chloride in groundwater was verified by comparison the results of automatic instruments and laboratory. The results show that the automatic monitoring results of each water quality parameter are basically consistent with laboratory after targeted measures such as changing the analysis method, improving the pre-treatment or optimizing the pipeline integration. It can provide experience and reference for further establishing a unified and standardized groundwater quality automatic monitoring technical system. |
Key words: Groundwater Water quality Automatic monitoring Applicable method |