摘要: |
建立DPX快速吸附萃取、程序升温(PTV)大体积进样与气相色谱/质谱(GC/MS)联用, SIM模式同时测定水中19种多溴联苯(PBBs
)单体的方法。该方法在PBBs质量浓度1~50 μg/L范围内线性良好,19种PBBs单体检出限为0.147~0.230 μg/L,相对标准偏差为6.61%~10.5%,加标回收率为61.5%~82.6%。 |
关键词: 多溴联苯 DPX萃取 程序升温大体积进样 GC/MS |
DOI: |
分类号:X832;O657.63 |
文献标识码:B |
基金项目:江苏省环境监测科研基金项目(1302) |
|
Application of DPX Rapid Extraction Tip for Determination of 19 PBBs in Water by Gas Chromatography Mass Spectrometry with Temperature Programming and Large Volume Injection |
董黎静
|
Abstract: |
DPX rapid adsorption extraction tip was combined with programmable temperature vaporizer (PTV) and large volume injection coupled with GC/MS to determine 19 polybrominated biphenyls (PBBs
) in water simultaneously. The experiment was conducted with the SIM mode. The experimental results showed good linearity ranging from 1 to 50 μg/L, and the detection limits of 19 PBBs monomer were between 0.147 and 0.230 μg/L. The relative standard deviation was between 6.61% and 10.5%. Standard addition recovery was in the range of 61.5% to 82.6%. |
Key words: PBBs DPX extraction Temperature programming and large volume GC/MS |