引用本文: | 王媛媛,王琪,李贝,梁晶,彭华,吴立业,李洁.恶臭国标测定方法和便携式恶臭测定仪测定结果的比对分析[J].环境监控与预警,2017,9(5):20-23 |
| WANG Yuan yuan, WANG Qi, LI Bei, LIANG Jing, PENG Hua, WU Li ye, LI Jie.Comparative Analysis of Odor Determination by National Standard Method and Portable Odor Tester[J].Environmental Monitoring and Forewarning,2017,9(5):20-23 |
|
摘要: |
比对了恶臭国标测定方法《GB/T 14675—1993》和便携式恶臭测定仪对厂界环境空气无组织排放臭气浓度的测定结果。结果显示,恶臭国标测定方法和便携式恶臭测定仪的测定值基本在同一范围内,具有一定的可比性,但2种方法在嗅辨方式、工作地点、结果计算方式、配气方法、样品原始性和测定范围上都存在差异。 |
关键词: 恶臭 国标方法 便携式恶臭测定仪 |
DOI: |
分类号:X831 |
文献标识码:B |
基金项目: |
|
Comparative Analysis of Odor Determination by National Standard Method and Portable Odor Tester |
WANG Yuanyuan, WANG Qi, LI Bei, LIANG Jing, PENG Hua, WU Liye, LI Jie
|
He nan Environmental Monitoring Center, Zhengzhou, Henan 450004, China
|
Abstract: |
The odor concentrations of fugitive emission were determinated both by national standard method 《GB/T 14675—1993》 and portable odor tester. Results showed that the measurement values of both national standard method and portable odor tester were basically within the same range, and have a certain comparability.But there were differences between the two methods, such as olfactory way, work place, result calculation, sample preparation, sample originality and measurement range. |
Key words: Odor National standard method Portable odor tester |