摘要: |
非甲烷总烃在监测过程中,废气样品保存容器的选择和保存时间的长短对分析结果有重要影响。研究结果表明:使用玻璃注射器保存样品,应在8 h内完成分析;使用泰德拉惰性气袋保存样品,保存时间可延长至48 h,如废气中主要组分为沸点高于150℃的高沸点化合物,则应在8 h内完成非甲烷总烃的测定。 |
关键词: 非甲烷总烃 废气 样品保存 |
DOI: |
分类号:X830.1 |
文献标识码:B |
基金项目:国家环境监测标准方法制修订资助项目(No.2001300101036) |
|
Discussion on Sample Preservation in Determination of Non Methane Hydrocarbons in Waste Gas |
PENG Tao, CHEN Lei
|
Yangzhou Environmental Monitoring Centre, Yangzhou, Jiangsu 225007, China
|
Abstract: |
The selection and storage time of sample storage containers have an important influence on the non methane hydrocarbons (NMHC) analytical results. The results show that: The glass syringe is less airtight, so the analysismust be completed within 8 h.In Tedlainert gas bag, if the main component's boiling point is higher than 150℃, the sample should be measured within 8 h,otherwise, within 48 h. |
Key words: on methane hydrocarbons Waste gas Sample preservation |