引用本文:YE Bing, HOU Peng, WU Hou-rong, QIAN Wei-yan, NIE Xin-longet al.Analysis on Water Removal Efficiency of Portable Dry Flue Gas Pretreatment Device[J].Environmental Monitoring and Forewarning,2022,14(3):59~62
【打印本页】   【HTML】   【下载PDF全文】   View/Add Comment  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 4536次   下载 1252 本文二维码信息
码上扫一扫!
分享到: 微信 更多
便携式干法烟气预处理装置除水效率分析
叶兵,侯鹏,吴厚荣,钱玮燕,聂新龙等1,2,3,4
1.江苏省南京环境监测中心,江苏 南京 210013;2.江苏省生态环境监测监控有限公司,江苏 南京 210019;3.建邺区环境保护监测站,江苏 南京 210019;4.武汉林海仪器设备工程公司,湖北 武汉430012
摘要:
利用湿度发生器与SO2标准气生成湿度梯度测试气,比较“微压”式、半导体冷凝、Nafion管干燥3种便携式烟气预处理装置中的SO2损失率;结合各预处理装置的工作原理及特点,分析其除水效率下降的主要原因。通过现场比对测试,验证“微压”式和半导体冷凝烟气预处理装置的除水能力。为降低烟气湿度对测试结果的影响,提高监测数据的准确性提供参考。
关键词:  “微压”式预处理  半导体冷凝预处理  Nafion管干燥预处理  除水效率  烟气  比对测试
DOI:
分类号:X831
基金项目:江苏省环境监测科研基金资助项目(2007)
Analysis on Water Removal Efficiency of Portable Dry Flue Gas Pretreatment Device
YE Bing, HOU Peng, WU Hou-rong, QIAN Wei-yan, NIE Xin-longet al1,2,3,4
1. Jiangsu Nanjing Environmental Monitoring Center, Nanjing,Jiangsu 210013, China;2. Jiangsu Ecological Environment Monitoring Co., Ltd., Nanjing, Jiangsu 210019, China;3. Nanjing Jianye District Environmental Protection Monitoring Station, Nanjing, Jiangsu 210019, China;4. Wuhan Linhai Instrument and Equipment Engineering Company, Wuhan, Hubei 430012, China
Abstract:
In order to observe the water removal efficiency of portable dry flue gas pretreatment device, the humidity generator and SO2 standard gas were used to generate humidity gradient test gas, and the SO2 loss rates of “micro pressure” type, semiconductor condensation and Nafion tube drying were compared. Combined with the working principle and characteristics of each pretreatment device, the main reasons for the decline of water removal efficiency were analyzed. Through the field comparison test, the water removal efficiency of the “micro pressure” type and semiconductor condensation type flue gas pretreatment device was verified, which provides a reference for reducing the impact of flue gas humidity on the test results and improving the accuracy of monitoring data.
Key words:  “Micro pressure” type  Semiconductor condensation  Nafion tube drying  Water removal efficiency  Comparison test